Parameter, Checksum, Version, Password - Siemens SINAMICS S120 Installation And Start-Up Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

SINAMICS Safety Integrated (Booksize)
General information about SINAMICS Safety Integrated
5.1.2

Parameter, checksum, version, password

Properties of Safety Integrated parameters
The following applies to Safety Integrated parameters:
S They are kept separate for each monitoring channel.
S They are password-protected against accidental or unauthorized changes.
S During ramp-up, a checksum (cyclic redundancy check: CRC) is generated and
checked via the safety parameters, which have undergone a checksum check.
S Data management
– Safety parameters for Control Unit
These parameters are stored on the non-volatile CompactFlash card.
– Safety parameters for Motor Module
These parameters are stored on the non-volatile CompactFlash card in a
separate file and format.
S Factory settings for safety parameters
You can only reset the safety parameters to the factory setting on a
drive-specific basis using p0970 or p3900 when the safety functions are not
enabled (p9601 = p9801 = 0).
Checking the checksum
For each monitoring channel, the safety parameters include one parameter for the
actual checksum for the safety parameters that have undergone a checksum
check.
During commissioning, the actual checksum must be transferred to the corre-
sponding parameter for the specified checksum.
S r9798
S p9799
S r9898
S p9899
During each ramp-up procedure, the actual checksum is calculated via the safety
parameters and then compared with the specified checksum.
If the actual and specified checksums are different, fault F01650 or F30650 is out-
put and an acceptance test requested.
5-152
Safety Integrated actual checksum SI parameters (Control Unit)
Safety Integrated setpoint checksum SI parameters (Control Unit)
Safety Integrated actual checksum SI parameters (Motor Module)
Safety Integrated setpoint checksum SI parameters (Motor Module)
SINAMICS S120 Installation and Start-Up Manual, 12/04 Edition