Diagnosis
Diagnostics using STARTER
Note
r0786[1] indicates the normalization per volt.
A change in the output voltage by 1 volt corresponds to the value in this
parameter. The units are determined by the interconnected test signal.
Example:
r0786 = 1500.0 and the measuring signal is r0063 (CO: Actual speed smoothed)
A change of 1 volt at the output of the measuring socket corresponds to
1500.0 rpm.
Parameter overview (see List Manual)
Variable parameters
S p0771[0...2]
S p0777[0...2]
S P0778[0...2]
S p0779[0...2]
S p0780[0...2]
S p0783[0...2]
S p0784[0...2]
Visualization parameters
S r0772[0...2]
S r0774[0...2]
S r0786[0...2]
Function diagram overview (see List Manual)
S 8134
6-216
CI: Test sockets signal source
Test socket characteristic value x1
Test socket characteristic value y1
Test socket characteristic value x2
Test socket characteristic value y2
Test sockets offset
Test socket limit on/off
Test sockets output signal
Test sockets output voltage
Test socket normalization per volt
Test sockets
SINAMICS S120 Installation and Start-Up Manual, 12/04 Edition
E Siemens AG, 2004. All rights reserved