Siemens SINAMICS S120 Installation And Start-Up Manual page 244

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Basic Information about the Drive System
BICO technology: interconnection of signals
Scaling for object A_Inf
Table 7-7
Scaling for object A_Inf
Size
Reference frequency
Reference voltage
Reference current
Reference power
Reference control factor
Reference temperature
Reference electrical angle
Scaling for object B_Inf
Table 7-8
Scaling for object B_Inf
Size
Reference frequency
Reference voltage
Reference current
Reference power
Reference temperature
Reference electrical angle
7-244
Scaling parameters
100 % = p2000
100 % = p2001
100 % = p2002
100 % = r2004
100 % = Maximum output voltage
without overload
100 % = 100°C
100 % = 90°
Scaling parameters
100 % = p2000
100 % = p2001
100 % = p2002
100 % = r2004
100 % = 100°C
100 % = 90°
SINAMICS S120 Installation and Start-Up Manual, 12/04 Edition
Default at first commissioning
p2000 = p0211
p2001 = r0206/r0207
p2002 = p0207
r2004 = p0206
-
-
-
Default at first commissioning
p2000 = 50
p2001 = r0206/r0207
p2002 = p0207
r2004 = p0206
-
-
E Siemens AG, 2004. All rights reserved

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents