Siemens SINAMICS S120 Installation And Start-Up Manual page 110

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Communication via PROFIBUS
Cyclic communication
Table 4-11
Description of A_STW1 (status word for A_INF), continued
Bit
Meaning
11
Bypass energized
12
12
Line contactor energized
Line contactor energized
13
14
Reserved
15
A_STW1 (status word for B_INF)
See function diagram [8926].
Table 4-12
Description of A_STW1 (status word for B_INF)
Bit
Meaning
0
0
Ready to power up
Ready to power up
1
1
Ready
Ready
2
2
Operation enabled
Operation enabled
3
3
Fault active
Fault active
4
4
No OFF2 active
No OFF2 active
5
Reserved
6
6
Power up inhibit
Power-up inhibit
7
7
Warning active
Warning active
8
Reserved
4-110
Comments
Bypass energized
Pre-charging is complete and the bypass
1
relay for the pre-charging resistors is
energized.
Bypass not energized
0
Pre-charging not yet complete
1
Line contactor energized
0
Line contactor not energized
-
-
Comments
1
Ready to power up
0
Not ready to power up
Ready
1
DC link pre-charged, pulses inhibited
0
Not ready
Operation enabled
1
Vdc = Vdc_setp
0
Operation inhibited
1
Fault active
0
No fault
1
No OFF2 active
0
OFF2 active
-
-
Power-up inhibit
1
Fault active
0
No power-up inhibit
1
Warning active
0
No alarm
-
-
SINAMICS S120 Installation and Start-Up Manual, 12/04 Edition
BICO
BO: r0899.11
BO: r0899.12
BO: r0899 12
-
BICO
BO: r0899.0
BO: r0899 0
BO: r0899.1
BO: r0899.1
BO: r0899.2
BO: r0899.2
BO: r2139.3
BO: r2139 3
BO: r0899 4
BO: r0899.4
-
BO: r0899.6
BO: r0899.6
BO: r2139.7
BO: r2139 7
-
E Siemens AG, 2004. All rights reserved