3.4.4

Commissioning with STARTER (example)

The table below describes the steps for commissioning the example with
STARTER.
Table 3-5
Commissioning sequence with STARTER (example)
What to do?
1. Automatic
Operator action:
configuration
–>
"Project"
–>
Double-click "Automatic configuration"
–>
Follow the instructions provided in the Wizard
2. Configure the
The supply must be configured.
supply
Name of supply
Click "Configure DDS".
2.1. Supply
The Wizard displays the data determined
Wizard
automatically from the electronic type plate.
You can now set the line/DC link identification.
You have to enter the device connection voltage
and rated line frequency.
This completes the configuration for the supply.
3. Configure
The drives must be configured individually.
drives
–>
"Drives"
"Configuration"
3.1. Control
You can activate the function modules.
structure
You can select the control type.
3.2. Power
The Wizard displays the data determined
section
automatically from the electronic type plate.
3.3. Motor
You can enter the name of the motor (e.g.
equipment ID).
Select standard motor from list: Yes
Select the motor type (see type plate).
3.4. Motor data
You can enter the motor data on the type plate here.
Induction motors (rotary):
If known, mechanical data for the motor and drive
line can be entered.
Synchronous motors (rotary, permanent-magnet)
If known, the data for a PE spindle can be entered.
E Siemens AG, 2004. All rights reserved
SINAMICS S120 Installation and Start-Up Manual, 12/04 Edition
Initial commissioning using servo (booksize) as an example
How to do it?
–>
"Connect to target system"
–>
Double-click "Configuration"
–>
–>
Drive name
Double-click
–>
Click "Configure DDS".
Commissioning
Comments
–>
If the line environment or DC
link components are
changed, line/DC link
identification should be
repeated.
You can select a standard
motor from the list of motors
or you can enter the motor
data yourself. You can then
select the motor type.
If you do not enter any
mechanical data, it is
estimated on the basis of the
data on the type plate.
The equivalent circuit
diagram data is also
estimated on the basis of the
data on the type plate or
determined by means of
automatic motor data
identification.