Diagnosis
Diagnostics using LEDs
6.1.9

Sensor Module Cabinet 30 (SMC30)

Table 6-10
Sensor Module Cabinet 30 – description of LEDs
LED
Color
OFF
Green
Continuous
Orange
Continuous
Red
Continuous
RDY
READY
Green/
Flashing
Red
2 Hz
Green/
Orange
Flashing
or
2 Hz
Red/
Orange
OFF
OUT >5 V
Orange
Continuous
6-200
Status
Electronics power supply is missing or outside
permissible tolerance range.
The module is ready for operation and cyclic
DRIVE-CLiQ communication is taking place.
DRIVE-CLiQ communication is being
established.
At least one fault is present in this module.
Note:
LED is driven irrespective of the corresponding
messages being reconfigured.
Firmware is being downloaded.
Module recognition via LED is activated (p0144).
Note:
Both options depend on the LED status when
module recognition is activated via p0144 = 1.
Electronics power supply is missing or outside
permissible tolerance range.
Power supply v5 V.
Electronics power supply for measuring system
available.
Power supply >5 V.
Notice
You must ensure that the connected encoder can
be operated with a 24 V supply. If an encoder
that is designed for a 5 V supply is operated with
a 24 V supply, this can destroy the encoder
electronics.
SINAMICS S120 Installation and Start-Up Manual, 12/04 Edition
Description, cause
E Siemens AG, 2004. All rights reserved
Remedy
-
-
-
Remedy and
acknowledge
fault
-
-
-
-

Hide quick links: