Analog Outputs - Siemens SINAMICS S120 Installation And Start-Up Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Basic Information about the Drive System
Inputs/outputs
Notice
Scaling parameters p4057 to p4060 do not limit the voltage values.
Function diagram overview (see List Manual)
S 9104
S 9566
S 9568
7.8.4

Analog outputs

p4071[0]
p4077[0]
p4080[0]
p4078[0]
Fig. 7-14
Analog outputs: signal processing using AO 0 of TB30/TM31 as an example
Properties
S Adjustable absolute-value generation
S Inversion via binector input
S Adjustable smoothing
S Adjustable transfer characteristic
S Output signal can be displayed via visualization parameter
7-260
Analog inputs (AI 0 and AI 1)
Analog input 0 (AI 0)
Analog input 1 (AI 1)
p4082 [0]
p4075 [0]
0
0
–1
1
1
p4079[0]
y
[V]
y
2
4mA
x
x
x
1
2
[%]
y
1
Scaling
current output
(e.g. TM31)
SINAMICS S120 Installation and Start-Up Manual, 12/04 Edition
p4073 [0] (0.0)
Smoothing
p4076[0]
p4083[0]
r4074[0]
Offset
0,2
D
3
4,5
Also for
E Siemens AG, 2004. All rights reserved
[%]
r4072 [0]
AO
A

Hide quick links: