Commissioning
Initial commissioning using vector (booksize) as an example
3.5.4

Commissioning with STARTER (example)

The table below describes the steps for commissioning the example with
STARTER.
Table 3-7
Commissioning sequence with STARTER (example)
What to do?
1. Automatic
Operator action:
configuration
–>
"Project"
–>
Double-click "Automatic configuration"
–>
Follow the instructions provided in the Wizard
2. Configure
The drives must be configured individually.
drives
–>
"Drives"
"Configuration"
2.1. Control
You can activate the function modules.
structure
You can select the control type.
2.2. Power
The Wizard displays the data determined
section
automatically from the electronic type plate.
2.3. BiCo power
Supply in operation
section
Control Unit: r0722.4 (digital input 4)
2.4. Drive setting
You can select the motor standard (IEC / NEMA)
and power section application (duty cycles).
2.5. Motor
You can enter the name of the motor (e.g.
equipment ID).
Enter motor data: Yes
Select motor type "1LAx".
2.6. Motor data
You can enter the motor data on the type plate here.
If known, mechanical data for the motor and drive
line can be entered.
Equivalent circuit diagram data: No
2.7. Motor brake
Here, you can configure the brake and activate the
"Extended brake control" function module.
3-62
How to do it?
–>
"Connect to target system"
–>
–>
Drive name
Double-click
–>
Click "Configure DDS"
SINAMICS S120 Installation and Start-Up Manual, 12/04 Edition
Comments
Caution
If a sinusoidal filter is
connected, it must be
activated here to prevent it
from being destroyed!
You can select a standard
motor from the list of motors
or you can enter the motor
data yourself. You can then
select the motor type.
If you do not enter any
mechanical data, it is
estimated on the basis of the
data on the type plate.
The equivalent circuit
diagram data is also
estimated on the basis of the
data on the type plate or
determined by means of
automatic motor data
identification.
For more information, see the
Function Manual.
E Siemens AG, 2004. All rights reserved