Siemens SINAMICS S120 Installation And Start-Up Manual page 100

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Communication via PROFIBUS
Cyclic communication
Table 4-5
Description of A_CTW1 (control word for A_INF), continued
Bit
Meaning
8
Reserved
9
Controlled by PLC
Controlled by PLC
10
Note:
This bit should not be set to "1" until the PROFIBUS slave has returned an appropriate status via
STW1.9 = "1".
11
12
13
Reserved
14
15
4-100
Comments
-
-
Controlled by PLC
This signal must be set so that the process data
1
transferred from the PROFIBUS master to the
slave is accepted and activated.
Not controlled by PLC
The process data transferred from the
0
PROFIBUS master are discarded by the slave,
i.e. they are assumed to be zero.
-
-
SINAMICS S120 Installation and Start-Up Manual, 12/04 Edition
-
BI: p0854
BI: p0854
-
E Siemens AG, 2004. All rights reserved
BICO