Removing The Optional Front 2.5-Inch Hot-Swap Hard Disk Drive Cage - Lenovo NeXtScale nx360 M5 Installation And Service Manual

Machine type 5465
Hide thumbs Also See for NeXtScale nx360 M5:
Table of Contents

Advertisement

Latch
Hook
Figure 63. RAID adapter battery holder installation
Step 4.
Replace the air baffle (see "Replacing the air baffle" on page 117).
Step 5.
Replace the cover (see "Installing the compute node cover" on page 115).
Step 6.
Slide the node into the rack.
Step 7.
Reconnect the power cords and all external cables, and turn on the server and peripheral devices.

Removing the optional front 2.5-inch hot-swap hard disk drive cage

Use this information to remove the optional front 2.5-inch hot-swap hard disk drive cage.
Before you remove the optional front 2.5-inch hot-swap hard disk drive cage, complete the following steps:
1. Read "Safety" on page v and "Installation guidelines" on page 101.
2. If the compute node is installed in a NeXtScale n1200 Enclosure, remove it (see "Removing a compute
node from a chassis" on page 104 for instructions).
3. Carefully lay the compute node on a flat, static-protective surface, orienting the compute node with
the bezel pointing toward you.
To remove the optional front 2.5-inch hot-swap hard disk drive cage, complete the following steps.
Step 1.
Remove the cover (see "Removing the compute node cover" on page 113).
Step 2.
Remove the hard disk drive(s) if there is any (see "Removing and installing drives" on page 164).
Step 3.
Pull up the plunger and slide the backplane inward to release the backplane.
Battery holder
Air baffle
Chapter 5
.
Removing and replacing components
141