Prefix: PLAT ID: 0036
User Response
1. Make sure that the fans are operating. There are no obstructions to the airflow (front and rear of
the server), the air baffles are in place and correctly installed, and the server cover is installed
and completely closed.
2. Make sure that the heat sink for microprocessor n is installed correctly.
3. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
• 806f0108-1501ffff : [PowerSupplyElementName] has Failed. (HSC Status)
This message is for the use case when an implementation has detected a Power Supply has failed.
May also be shown as 806f01081501ffff or 0x806f01081501ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0086
User Response
1. Reseat power supply n.
2. If the power-on LED is not lit and the power-supply error LED is lit, replace power supply n.
3. If both the power-on LED and the power-supply error LED are not lit, see Power problems for
more information. (n = power supply number)
• 806f0109-1301ffff : [PowerSupplyElementName] has been Power Cycled. (Host Power)
This message is for the use case when an implementation has detected a Power Unit that has been
power cycled.
May also be shown as 806f01091301ffff or 0x806f01091301ffff
Severity