Lenovo NeXtScale nx360 M5 Installation And Service Manual page 194

Machine type 5465
Hide thumbs Also See for NeXtScale nx360 M5:
Table of Contents

Advertisement

2. If the compute node is installed in a NeXtScale n1200 Enclosure, remove it (see "Removing a compute
node from a chassis" on page 104 for instructions).
3. Carefully lay the compute node on a flat, static-protective surface, orienting the compute node with
the bezel pointing toward you.
Note: PCI riser-cage brackets must be installed even if you do not install a GPU adapter.
To install a PCI riser-cage assembly to the GPU tray, complete the following steps:
Step 1.
Remove the cover (see "Removing the compute node cover" on page 113).
Step 2.
Install the GPU adapter in the new PCI riser-cage assembly (see "Replacing an adapter/GPU
adapter" on page 187).
Step 3.
Remove the PCI filler panel, if one is present, from the server.
Step 4.
Re-install the GPU tray into the compute node (see "Installing a GPU tray into a compute node" on
page 110).
Step 5.
Align the PCI riser-cage assembly with the PCI riser connector on the GPU tray; then, grasp the
rear side of the PCI riser-cage touch point and the front PCI riser-cage suitable location of the PCI
riser-cage assembly.
Step 6.
Press down firmly until the PCI riser-cage assembly is seated correctly in the connector on the
system board.
Front PCI riser
assembly
Figure 112. Front PCI riser-cage assembly installation
180
Lenovo NeXtScale nx360 M5 Installation and Service Guide

Advertisement