Lenovo NeXtScale nx360 M5 Installation And Service Manual page 364

Machine type 5465
Hide thumbs Also See for NeXtScale nx360 M5:
Table of Contents

Advertisement

This message is for the use case when an implementation has detected a Processor Failed - IERR
Condition.
May also be shown as 806f00070302ffff or 0x806f00070302ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0042
User Response
1. Update the latest level of system firmware and device drivers are installed for all adapters and
standard devices, such as UEFI, IMM Ethernet,and SAS. Important: Some cluster solutions
require specific code levels or coordinated code updates. If the device is part of a cluster
solution, verify that the latest level of code is supported for the cluster solution before you
update the code.
2. Run the DSA program.
3. Reseat the adapter.
4. Replace the adapter.
5. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
6. (Trained technician only) Replace the system board.
• 806f0009-1301ffff : [PowerSupplyElementName] has been turned off. (Host Power)
This message is for the use case when an implementation has detected a Power Unit that has been
Disabled.
May also be shown as 806f00091301ffff or 0x806f00091301ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
350
Lenovo NeXtScale nx360 M5 Installation and Service Guide

Advertisement

Table of Contents
loading