PCI riser cage
Figure 109. PCI riser-cage assembly installation
Step 5.
Replace the cover (see "Installing the compute node cover" on page 115).
Step 6.
Slide the server into the rack.
Step 7.
Reconnect the power cords and any cables that you removed.
Step 8.
Turn on the peripheral devices and the server.
Removing a PCI riser-cage assembly from the GPU tray
Before you remove a PCI riser-cage assembly from the GPU tray, complete the following steps:
1. Read "Safety" on page v and "Installation guidelines" on page 101.
2. If the compute node is installed in a NeXtScale n1200 Enclosure, remove it (see "Removing a compute
node from a chassis" on page 104 for instructions).
3. Carefully lay the compute node on a flat, static-protective surface, orienting the compute node with
the bezel pointing toward you.
Note: PCI riser-cage brackets must be installed even if you do not install a GPU adapter.
To remove a PCI riser-cage assembly from the GPU tray, complete the following steps:
Step 1.
Remove the cover (see "Removing the compute node cover" on page 113).
Step 2.
Grasp the rear side of the PCI riser-cage touch point and the front PCI rise-cage suitable location
of the PCI riser-cage assembly. Use your thumb to press down the right hand side bezel (a tiny
square surface) of the GPU tray; then lift it out of the PCI riser-cage out of the GPU tray.