Lenovo NeXtScale nx360 M5 Installation And Service Manual page 324

Machine type 5465
Hide thumbs Also See for NeXtScale nx360 M5:
Table of Contents

Advertisement

• 80010901-3707ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has
asserted. (HDD Outlet Temp)
This message is for the use case when an implementation has detected an Upper Critical sensor going
high has asserted.
May also be shown as 800109013707ffff or 0x800109013707ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0494
User Response
1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and
rear of the server), that the air baffle is in place and correctly installed, and that the server cover
is installed and completely closed.
2. Check the ambient temperature. You must be operating within the specifications (see Server
Features and specifications for more information).
3. Make sure that HDD is installed correctly.
4. (Trained technician only) Replace system board.
80010902-0701ffff : Numeric sensor [NumericSensorElementName] going high (upper critical)
has asserted. (SysBrd 12V)
This message is for the use case when an implementation has detected an Upper Critical sensor going
high has asserted.
May also be shown as 800109020701ffff or 0x800109020701ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Voltage
310
Lenovo NeXtScale nx360 M5 Installation and Service Guide