Lenovo NeXtScale nx360 M5 Installation And Service Manual page 538

Machine type 5465
Hide thumbs Also See for NeXtScale nx360 M5:
Table of Contents

Advertisement

• 806f060d-0411ffff : Array [ComputerSystemElementName] has failed. (SDHV Drive 2)
This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d0411ffff or 0x806f060d0411ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
• 806f060d-0412ffff : Array [ComputerSystemElementName] has failed. (SDHV Drive 3)
This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d0412ffff or 0x806f060d0412ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
524
Lenovo NeXtScale nx360 M5 Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents