These are the Fault Codes for the Door Board.
F500
5 0 0
F501
5 0 1
F502
5 0 2
F503
5 0 3
F504
5 0 4
F505
5 0 5
F506
5 0 6
F507
5 0 7
F508
5 0 8
F509
5 0 9
F510
5 1 0
F511
5 1 1
F512
5 1 2
F513
5 1 3
F514
5 1 4
N/A: Not applicable to any model. Disregard.
temperature.
Flow meter missing.
Flow meter pulsing with no water
dispensing.
Ice/water stops dispensing
based on time (7 minute time
out).
hot water tank
N/A
N/A
Cold Water paddle switch input
missing
Cold Water paddle switch input
present
Hot Water T&P Switch input
missing
Hot Water T&P Switch input
present
Door Board Icemaker Mold temp
invalid
Door Board Ice Box Thermistor
invalid
Door Board HotWater1
Thermistor invalid
Door Board HotWater2
Thermistor invalid
– 118 –
Hot water time limit expires and
temperature not reached.
during dispense.
Runs the Diagnostic test 1
minute after a dispense.
If the dispense stops due to a
time out.
without tripping the level sensor.
Check paddle switch and wiring.
Check paddle switch and wiring.
Check T&P switch and wiring.
Check T&P switch and wiring.
Thermistor temperatures do not
match.
Thermistor temperatures do not
match.