GEAppliances CFE28TSH Technical Service Manual page 43

French door refrigerators
Table of Contents

Advertisement

K-CUP® brewing.
and two tank vent valves are used pressurize the
upper reservoir.
hot
The
just below the Hot Water Outlet valve with tubing to
the Hot Water Outlet and Valve. The Pressure Relief
Valve opens at 20 PSI should the hot water outlet
become blocked or the Pod is not punctured on the
top or bottom by the Brew Module.
The Pressure Relief Valve opens at ~20 PSI and
water will be released into the tank and valve
compartment. The consumer may observe water
on the top left of the mullion or the bottom of the
door. Should this occur check for obstructions in
the hot water outlet tubing, the bracket and motor
assembly or the pins in the brew module.
UI (User Interface) Components
The User Interface on the dispenser door has
a touch screen board mounted to a housing
containing the buttons and hot water knob.
To remove the UI, pull out rotate the left side of the
trim clockwise, then release from around the knob.
– 43 –
is a safety device located
(Continued next page)

Hide quick links: