Compressor and fan speeds will vary with
cabinet temperatures until the set temperature is
obtained.
After 6 hours of compressor run time (door
openings not counted), both the fresh food and
freezer will enter a heated defrost cycle.
When cooling is required, the main control board
moves the 3-way valve to either the A position
(supplying refrigerant to both fresh food and
freezer evaporators), or the B position (supplying
only the freezer evaporator), depending upon
compartment temperatures.
The compressor and fan(s) are delayed for 3
minutes before restarting.
When only the fresh food temperature is
3-way valve will move to the B
position (supplying only the freezer evaporator)
to continue cooling the freezer. Fresh food cycle
defrost will begin.
When the freezer and fresh food temperatures
compressor and fans will turn
3-way valve will move to the D position,
sounds.
After the accumulated compressor run time
(including door openings) has been reached, the
unit will begin the defrost pre-chill cycle.
: (1 second of door-open time = 100 seconds of
compressor run time.)
The fresh food cycle defrost occurs between
heated fresh food defrost cycles to reduce
excessive frost accumulations on the fresh food
evaporator.
During the fresh food cycle defrost, the
evaporator fan runs and there is no refrigerant
evaporator.
The fresh food cycle defrost does not use the
fresh food defrost heater.
The fresh food cycle defrost will occur any time
the temperature in the fresh food compartment
The fresh food cycle defrost does not occur when
the
After accumulating 32 hours of compressor
run time (actual compressor run time and door
openings), the operating system will enter freezer
pre-chill.
The pre-chill will occur whether the last freezer
defrost was normal or abnormal.
Pre-chill time will vary from 10 to 60 minutes,
depending on door openings and compartment
temperatures during pre-chill.
Any compressor run time prior to the beginning
of pre-chill does not count in the pre-chill time.
There is a 6 second delay after the compressor
the defrost heaters.
The ice box fan will run at HIGH speed whenever
the ice box cooling is needed during the pre-chill
cycle.
Pre-chill ends when either the maximum time
expires, the evaporator pre-chill temperature is
met, or the freezer pre-chill temperatures is met.
Fresh food only heated defrost occurs after 32
hours of compressor run time.
A freezer pre-chill will run before the fresh food
only heated defrost.
Providing that the previous freezer and/or fresh
food heated defrost cycles were normal, the
freezer will defrost with every third fresh food
defrost cycle.
Fresh food only heated defrost occurs 32, 64,
and 96 hours after defrosting both the fresh
food and the freezer together.
– 58 –
(Continued next page)