F1
1
F2
2
F3
3
F4
4
F5
5
F6
6
F7
7
F8
8
F9
9
1 0
F11
1 1
F12
1 2
FZ Evap.
OPEN or
Thermistor
short
FF Evap.
OPEN or
Thermistor
short
: Not applicable to any model. Disregard.
: F10 not on Café.)
FF1 Thermistor Invalid
N/A
FZ Cabinet Thermistor Invalid
FZ Evaporator Thermistor
Deli Pan Thermistor Invalid
FF Evaporator Thermistor Invalid
N/A
Ambient Temperature Invalid
Ambient Humidity Invalid
FZ Icemaker Mold Body
Thermistor (MB) Invalid
N/A
N/A
FZ Evaporator Thermistor: This will impact defrost only as follows:
1. All FZ heater defrosts will be 20 minutes.
2.
FZ Evaporator Thermistor: This will impact FF defrost only as follows:
1. All FF heater defrost will be 20 minutes.
2.
– 114 –
•
An invalid thermistor fault code is
generated when a thermistor is
either shorted, open or falls outside
of the normal operating range.
•
A thermistor must return to the
normal range and go out of range
to generate another fault count.
•
Any time an error code is cleared,
the fault code can be set again
immediately if the thermistor is still
invalid.