GEAppliances CFE28TSH Technical Service Manual page 42

French door refrigerators
Table of Contents

Advertisement

J. Hot water from the Hot Water tank passes
into the brewer.
K. Hot water mixes with contents of the beverage
pod.
L. Hot beverage is dispensed into cup or container
sitting on the shelf below.
DOOR BOARD
(top edge of door)
AC
Door Icemaker
Chilled Water
Temp Controled
Hot Water
Water from either outlet of the double valve passes
the double valve enters the Flow Control from the
bottom and exits from the outlet on the right. This
K
Flow Control for temperature selected hot water.
The water from the right outlet of the valve enters
the Flow Control from the left and exits from the
K-Cup brewing to the hot water tank.
NOTE: The ?Flow Control is factory set,
attempt to adjust.
– 42 –
FEATURE BOARD
(bottom edge of door)
AC
Keurig ® K-CUP®
J202-3
SS WATER VALVE
J202-2
J203-1
SS HEATER
J203-2
SILVER/VIOLET
125
.39K
.39K
.39K
.39K
Café: 19
SS: 12
J8-2
HOT WATER HTR
(Continued next page)
Line Neutral
BROWN/
WHITE
DISP VLV
SS

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents