GEAppliances CFE28TSH Technical Service Manual page 40

French door refrigerators
Table of Contents

Advertisement

meter.
If after 3 seconds the control does not see
Water feature, the main board will deactivate
the isolation water valve, the door board will
deactivate the hot water valve, the control will
deactivate the Hot Water feature and set a fault
code.
The controls must measure ¼ ounce per second
while dispensing a minimum of 5 ounces of cold
Hot Water feature will be deactivated.
The control will deactivate the Hot Water feature
if the time to dispense 10 ounces of cold water
is greater than 45 seconds.
If the Hot Water feature is deactivated the
icemaker & chilled water systems are still active.
Hot Water is deactivated the control displays
The Hot Water feature can be reactivated by
dispensing 7 ounces of cold water within 28
seconds to restoring all of its functions.
The control measures the total water volume
and the time from the beginning to the end of all
dispenses and displays the volume.
Maximum water heating time is 8 minutes.
Minimum water heating time of 1 minute will be
displayed on the screen.
Maximum amount of hot water available to
dispense is 10 ounces.
30 seconds later chime again then again at
1 minute if Hot Water is still not dispensed or
canceled, it will chime again at 2, 3, 4, 5, 6, 7
minutes, at 8 minutes hot water is canceled
without any sound.
While heating water if the consumer presses
one of the buttons on the user interface; Water,
Crushed, Cubed, Lock, Precise Fill, or Hot Water,
the
Cancel?' and continue to heat.
terminate water heating then go to the
refrigerator home screen and the control will
execute the selected function.
will revert to the previous screen and the control
will continue hot water operation.
The Hot Water system is not active while the
The USB uploading of photos is disabled while
the control is in Hot Water Dispense mode.
(actually dispensing hot water)
If a Hot Water system fault occurs the UI screen
manual for fault codes)
The Hot Water heating countdown time is only
an estimate displayed in 15 minute intervals.
Countdown timer can hold for more than 15
seconds at any time or skip a 15 second interval.
(Examples: timer could hold at 1 minute for 25
seconds; the time could go from 45 seconds to
15 seconds skipping 30 seconds)
water.
temperature depending on its size and
constitution.
Both of the thermistors must have a valid
temperature reading for the Hot Water system
to perform any operation.
– 40 –
LCD screen
LCD screen
(Continued next page)