6. Rotate the water valve and remove the Phillips
7.
meter out from the coupling.
8.
9.
pulling the inlet water line out from the coupling.
10.
Clip
Disconnect
Collar
– 100 –
water and supplies this water to the freezer
icemaker. The valve coil has an approximate
resistance value of 400 W.
The freezer icemaker water valve is located in the
machine compartment to the right of the condenser
and is attached to the isolation valve bracket.
1. Remove the machine compartment cover (see
Machine Compartment Cover).
2. Remove the 1/4 in. hex head screw and valve
assembly from the cabinet.
3.
remove the 1/2 in. nut that attaches the water
supply line to the isolation water valve.
4. Disconnect the water valve wire harness.
5. Remove the plastic lock clips from the couplings,
then carefully push each collar in while pulling
each water line out from the valve.
See note on page 78 regarding lock clips.
6. Remove the two Phillips-head screws from
bracket.
Disconnected
Harness
Lock Clip
Collar
Freezer Icemaker
Water Valve
1/2 in. nut
Collar