Programming
Syntax
path acceleration
$AC_PATHACC =
Functionality
Real-time-event path acceleration is set via the channel-specific system variables.
Path acceleration
Parameter:
Value range: Path acceleration ≥ 0
2
Unit: m/s
Deactivation: $AC_PATHACC = 0
Application:
Part program
Static synchronized action
Reset response
Real-time-event path acceleration is deactivated on reset.
Supplementary conditions
Programming $AC_PATHACC in the part program automatically triggers a preprocessing stop with REORG
(STOPRE).