DL (additive tool offset)
- - -
- - -
Remarks:
The additive tool offset selected with DL refers to the active D number.
8)
See "Meaning of footnotes" at the end of the overview.
Application
Selection of the additive tool offset with reference to an active tool offset.
Further information
•
Initial setting: DL = 0
•
DL values cannot be output to the PLC via synchronized actions.
•
Default setting of the additive tool offset without an active DL function:
MD20272 $MC_SUMCORR_DEFAULT (basic setting of the additive offset without a program)
•
Deselection of the additive tool offset: DL = 0
•
DL function-specific machine data:
MD22252 $MC_AUXFU_DL_SYNC_TYPE (output time DL functions)
F functions
F (feedrate)
Address extension
Value range
Meaning
- - -
- - -
Remarks:
- - -
8)
See "Meaning of footnotes" at the end of the overview.
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
0 ... 6
Value
Value range
0.001 ... 999 999.999
H2: Auxiliary function outputs to PLC
8.1 Brief description
INT
Selection of the
additive tool offset
Type
Meaning
REAL
Path feed
1
8)
Number
6
397