D1: Diagnostics tools
5.3 Service overview
Speed lower than threshold setting
Status display of drive.
State 0: The actual speed value is greater than the threshold speed.
Status 1: The actual speed value is smaller than the threshold speed.
The threshold speed corresponds to machine datum:
MD1417 $MD_SPEED_THRESHOLD_X
(n
for 'n
< n
' message).
x
actual
x
Display corresponds to NST DB31, ... DBX94.5 ("|n
References:
/FB1/ Function Manual Basic Functions; Various Interface Signals (A2)
Actual speed = set speed
Status display of drive.
State 0:
The actual speed value is outside the speed tolerance band after a
new speed setpoint was defined.
State 1:
The actual speed value has reached the speed tolerance band after a new
speed setpoint was defined.
The speed tolerance band corresponds to machine datum:
MD1426 $MD_SPEED_DES_EQ_ACT_TOL (tolerance band for 'n
Display corresponds to NST DB31, ... DBX94.6 ("|n
References:
/FB1/ Function Manual Basic Functions; Various Interface Signals (A2)
Variable signal 1
Status display of 611D variable signaling function.
With the variable signaling function, any memory location can be monitored to see whether a definable threshold
is exceeded. In addition to the threshold, a tolerance band can be defined which is also taken into account when
scanning for violation of the threshold value. The signal can be combined with an ON delay or OFF delay time.
State 0: Threshold value not reached
State 1: Threshold value exceeded
Parameters for the variable signal function are set using the following 611D machine data:
MD1620 $MD_PROG_SIGNAL_FLAGS
MD1621 $MD_PROG_SIGNAL_NR
MD1622 $MD_PROG_SIGNAL_ADDRESS
MD1623 $MD_PROG_SIGNAL_THRESHOLD
MD1624 $MD_PROG_SIGNAL_HYSTERESIS
MD1625 $MD_PROG_SIGNAL_ON_DELAY
MD1626 $MD_PROG_SIGNAL_OFF_DELAY
286
< n
").
actual|
x
-n
set
actual
|= n
").
actual
set
(Bits variable signal function)
(Signal number variable signal function)
(Address variable signal function)
(Threshold variable signal function)
(Hysteresis variable signal function)
(ON Delay variable signal function)
(OFF Delay variable signal function)
Function Manual, 09/2011, 6FC5397-0BP40-2BA0