Plc Status - Siemens SINUMERIK 828D Function Manual

Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

D1: Diagnostics tools

5.5 PLC status

5.5
PLC status
PLC status signals can be checked and altered via the operator panel in the "Diagnostics" operating area.
Application
The end customer or service personnel can use this function on site without a programming device to do the
following:
Check the input and output signals of the PLC I/Os.
Carry out limited troubleshooting
Check the interface signals for diagnostic purposes.
Operation
For information about status display operation and changing PLC signals, refer to the Operator's Guide for the
relevant HMI software.
Status display
The status of the following data can be displayed on the operator panel.
Interface signals from the machine control panel
Interface signals to the machine control panel
Interface signals between the NCK and PLC
Interface signals between the HMI and PLC
Data blocks (DB 0-127)
Flags (FB 0-255)
Timers (T 0-127)
Counters (C 0-63)
Inputs (IB 0-127)
Outputs (QB 0-127)
For a breakdown of the interface signals (DBx, DBBy), refer to:
References:
/LIS2/ Lists (Volume 2)
Change in status
The status of the above signals can be changed for test purposes. Signal combinations are also possible. A
maximum of ten operands can be altered at any one time.
292
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
Basic Functions

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840d sl

Table of Contents