3.4.5
Dynamic response mode for path interpolation
Function
Technology-specific, dynamic response settings can be saved in machine data and can be activated in the part
program via the commands from G function group 59 (dynamic response mode for path interpolation).
Command
Activates the dynamic response settings for:
Standard dynamic response settings
DYNNORM
Positioning mode, tapping
DYNPOS
Roughing
DYNROUGH
Finishing
DYNSEMIFIN
Smooth finishing
DYNFINISH
Note
The dynamic response of the path axes alone is determined by the commands from G
function group 59 (dynamic response mode for path interpolation). They have no effect on:
•
Positioning axes
•
PLC axes
•
Command axes
•
Movements based on axis coupling
•
Overlaid movements with handwheel
•
JOG movements
•
Reference point approach (G74)
•
Fixed point travel (G75)
•
Rapid traverse movements (G0)
The standard dynamic response setting (DYNNORM) always takes effect for these axis
movements.
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
B1: Continuouspath Mode, Exact Stop, LookAhead
3.4 Dynamic adaptations
191