Path Acceleration For Real-Time Events (Channel-Specific); General Information - Siemens SINUMERIK 828D Function Manual

Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

B2: Acceleration
4.2 Functions
4.2.7

Path acceleration for real-time events (channel-specific)

4.2.7.1

General Information

General Information
So that no compromise has to be made between machining-optimized acceleration on the one hand and time-
optimized acceleration in connection with the following real-time events on the other:
NC-STOP / NC-START
Changing the feedrate override
Changing the velocity default for "safely reduced velocity" within the context of the "Safety Integrated" function
for the real-time events mentioned, the path acceleration can be specified using a channel-specific system
variable:
path acceleration
$AC_PATHACC =
Real-time event acceleration will only be active for the duration of the change in velocity in respect of one of the
real-time events specified above.
Limiting
If the specified path acceleration exceeds the capabilities of the machine axes that are of relevance for the path,
a limit will be imposed on the path acceleration within the control so that the resulting axial acceleration (a
restricted to less than 2x the parameterized maximum axial value (a
a
= 2 * a
with a
res
max,
max
Note
Real-time-event path acceleration is enabled, irrespective of the radial acceleration.
Effectiveness
Effective
Real-time event acceleration is only enabled in AUTOMATIC and MDA operating
modes in conjunction with the following real-time events:
NC-STOP / NC-START
Override changes
Changing the velocity default for "safely reduced velocity" within the context of the
"Safety Integrated" function
Not effective
Path acceleration for real-time events is ineffective for changes in path velocity that are
attributable to path planning during preprocessing for the channel, such as contour
curvatures, corners, kinematic transformation limitations, etc.
Real-time-event path acceleration is ineffective if the programmed value is smaller
than the path acceleration calculated during preprocessing for the path section
concerned.