3.6

Post processing of migrated GUD variables

After you have migrated a WinCC flexible project with GUD tags in the TIA Portal, you must
create a Creating a user database for global user data (Page 83) and reconnect the GUD
tags in the "HMI tags" editor.
Requirement
● A user database with GUD tags suitable to the TIA Portal project is available.
See Creating a user database for global user data (Page 83).
Procedure
To edit the migrated GUD tags, follow these steps:
1. In the project navigation in folder "HMI tags" click on the command "Show all tags", e.g.
"PC system_1 > HMI_RT_1 > HMI tags > Show all tags".
The editor "HMI tags" is opened, in which all tags are on display, including migrated GUD
tags.
2. In the "Address" field, click on the "Expand" symbol.
The dialog for selecting the SINUMERIK tags opens. You can find the migrated GUD tags
under "GUD: dynamic user data".
Figure 3-2
3. Navigate through the structure to the desired tag, select it and click the "Confirm" icon.
4. Click on the "Expand" icon in the "Address" field for each migrated tag, and select the
GUD tag to be addressed.
SINUMERIK Integrate Create MyHMI / WinCC V13 SP1
Configuration Manual, 11/2014
Dialog for selecting SINUMERIK tags with GUD
3.6 Post processing of migrated GUD variables
Migrating HMI projects
39