Advertisement

Configuring variables
6.3 Configuring GUD tags
Procedure overview
To use GUD in the TIA Portal, proceed as follows:
Step
Description
1
Provide the NC data as DEF files. To do this, you have the following options:
Using SINUMERIK Operate, export any existing DEF files from the NCU and copy them to the configuration
PC.
See Copying GUD to the configuration PC (Page 83).
Create new DEF files directly on the configuration PC.
2
Create a GUD database using the GUD TOOL "WinCC import NC userdata".
See Creating a user database for global user data (Page 83).
3
Open the "HMI Tags" editor and enter the tag names of the imported GUD tags.
Result
The GUD tags have been imported, and can be selected in the "Address" field of the NC
connection in the "HMI Tags" editor.
If you have specified the tag name in the "HMI Tags" editor, you can address the tags using
their symbolic names.
To modify the GUD later, you need to create a new user database. See Subsequently
changing definition files (Page 86).
See also
Post processing of migrated GUD variables (Page 39)
82
SINUMERIK Integrate Create MyHMI / WinCC V13 SP1
Configuration Manual, 11/2014