AcknowledgeNCCancelAlarms

Description
This function is used to acknowledge all cancel alarms pending for the specified connection
in a single action.
Parameter
Connection
9.5.8

SetNCUserFrame

Description
The data for zero point offsets is activated for a channel.
On entry, these variables are initially stored in a temporary memory on the NC. The
SetNCUserFrame function completely activates the newly-entered values and can be read
subsequently.
With this PI service, only one work offset can be activated. If several work offsets are set in
succession and then the "SetNCUserFrame" PI service issued, then only the parameters of
the last set work offset are activated.
You should set all parameters of one work offset and then issue the "SetNCUserFrame" PI
service, and then write the value of another work offset.
Parameter
Connection
Channel
Procedure on the HMI device
After the HMI device operator has entered the data for the work offsets in the HMI device
and pressed the configured key, the work offset data is accepted for the specified channel.
SINUMERIK Integrate Create MyHMI / WinCC V13 SP1
Configuration Manual, 11/2014
Configuring PI services of the NC as system functions
Meaning
Name of the connection to the NC.
Meaning
Name of the connection to the NC.
Channel to be activated (constant or variable): 1 - max 10