6.3.3.2

Copying GUD to the configuration PC

The following describes the basic procedure for copying the DEF files from the NCU.
Requirement
● In SINUMERIK Operate, the USB port is enabled under "Commissioning > HMI >
Log.Drive."
● A USB flash drive is plugged in.
Procedure
To make the GUD on the NCU available to the TIA Portal, proceed as follows:
1. Select the "Definitions" directory from the SINUMERIK Operate user interface in the
operating area "Commissioning > System data > NC data", and press the "Copy" softkey.
The "Definitions" directory is copied to the clipboard with all DEF files.
2. Select the USB flash drive in the folder structure, then press the "Paste" softkey.
The "Definitions" directory is copied to the USB flash drive.
6.3.3.3

Creating a user database for global user data

Requirement
● The current DEF files from the NCU are available on the PG/PC.
● The TIA Portal project in which the GUD tags are to be used has been created but it is
closed.
SINUMERIK Integrate Create MyHMI / WinCC V13 SP1
Configuration Manual, 11/2014
Configuring variables
6.3 Configuring GUD tags