Example: Program Started Later Than Programmed Start Time
This display informs you of the expired start time. The sampler presents this display for a short time, then advances to
the next display.
This display reports the number of samples that will be skipped if you do not change the start time; it appears only if
more than one sample event time has passed.
1. Select "YES" if you want to change the start time. Select "NO" if missed samples are acceptable.
2. This display appears when you select "YES" in display #142 and a sample event is to occur at the start time.
Enter the new start time.
3. This display appears when you select "YES" in display #142 and no sample is to occur at the start time for a
flow-paced sampling routine. Enter the new start time.
halted, the sampler will inform you with the message illustrated
below
The sampler will initiate one sample event if it missed one
.
or more sample events.
2
PAST START TIME . . .
1
SAMPLES WILL BE
SKIPPED
CHANGE START TIME?
[
, NO ]
YES
TAKE FIRST SAMPLE AT
12
:30
19-JUN
START FLOW COUNT AT
12
:30
19-JUN
3700 Portable Samplers
Section 3 Programming Guidelines
SAMPLES WILL BE
SKIPPED
Display 142
Display 93
Display 9