Example: Flow-Paced Sampling / Time-Based Bottle Sets
/
1. Press
ENTER
PROGRAM
2. Access the program sequence by selecting "PROGRAM."
3. Select "FLOW."
4. Enter "1000" to set the pulse interval to 1000 pulses.
5. Enter "2" to set the bottles per sample event to 2. Each bottle set will consist of two bottles.
6. Select "TIME."
7. Enter "2" to switch bottle sets every two hours. Press the
8. Press
/
ENTER
PROGRAM
9. Enter "100" to set the sample volume at 100 ml.
10. Select "NO."
11. Select "YES."
12. Enter the time at which you want the sampler to move to the second bottle set. At the first bottle set change,
12:00, the bottle set changes will be placed on schedule.
After this message is displayed briefly, the sampler will automatically return to the standby state.
13. When the sampler has been correctly installed, press the
to access the interactive state.
. . . STANDBY . . .
10:34:50
[
PROGRAM
SAMPLER
[ TIME ,
PACED SAMPLING
SAMPLE EVERY
1000 PULSES
2
BOTTLES PER
SAMPLE EVENT ( 1 - 24 )
CHANGE SETS BASED
ON [ TIME ,
CHANGE SETS EVERY
2
HOURS 0 MINUTES
to accept an entry of "0" for minutes.
CHANGE SETS EVERY
2 HOURS
SAMPLE VOLUMES OF
100
ml
EACH
ENTER START TIME?
[ YES ,
ENTER FIRST SWITCH
TIME?
FIRST SET CHANGE AT
12
:00
PROGRAMMING SEQUENCE
COMPLETE
. . . STANDBY . . .
10:37:23
Section 3 Programming Guidelines
19-JUN-04
, CONFIGURE ]
, STORM ]
FLOW
( 1 - 9999 )
]
SAMPLES/BTL
/
key to advance to the minutes entry.
ENTER
PROGRAM
0
MINUTES
( 10 - 330 )
]
NO
[
, NO ]
YES
19-06 JUN
key to run the program.
START SAMPLING
19-JUN-04
3700 Portable Samplers
3-87