Configure Option
Programming Mode Function
Set Clock
Basic & Extended
Bottles and Sizes
Basic & Extended
Suction Line
Basic & Extended
Liquid Detector
Basic & Extended
Programming Mode
Basic & Extended
Load Stored
Extended
Program
Save Current
Extended
Program
Flow-Mode
Extended
Sampling
Nonuniform Time
Extended
Calibrate Sampler
Basic & Extended
Sampling
Extended
Stop/Resume
Start-Time Delay
Basic & Extended
Enable Pin
Basic & Extended
Event Mark
Basic & Extended
Purge Counts
Basic & Extended
Tubing Life
Basic & Extended
Program Lock
Basic & Extended
Sampler ID
Basic & Extended
Run Diagnostics
Basic & Extended
Table 3-1 Configure Option Functions
Sets the sampler's real-time clock.
Sets the sampler for Portable or Compact configuration. Sets the
number and size of bottles used in the tub or inner sleeve.
Sets the type of line (vinyl or TEFLON), line diameter (
inch), and line length (3 to 99 feet).
Enables/disables liquid detector, sets the number of rinse cycles (0
to 3), enables/disables the suction-head entry, and sets the number
of sampling retries (0 to 3).
Sets the programming mode: basic or extended.
Loads one of as many as three previously saved sampling pro-
grams.
Saves current sampling program.
Directs sampler to take a sample at the beginning of a flow-paced
program. Directs sampler to sample at time-switches.
Directs sampler to accept nonuniform intervals as specific clock
times or in minutes.
Enables/disables the calibration sequence.
Enables/disables Sampling Stops and Resumes feature.
Sets the start time delay (from 0 to 9999 minutes). If no specific
start time is entered in the program sequence, the program uses the
entered start-time delay. The delay is the amount of time that will
elapse after you press the start sampling key or after the sampler is
enabled.
Directs the sampler to take a sample when disabled and/or enabled
by a Liquid Level Actuator or other Isco Flow-monitoring equipment.
Allows you to restart the sampling interval when the sampler is
enabled.
Allows you to select one of four types of event marks.
Adjusts the number of pre- and post-sample purge counts.
Displays the pump tubing life information. Resets the tubing life
count.
Enables/disables the password protection for input displays.
Allows you to enter a 10-character ID number for the sampler.
Tests the RAM, ROM, pump, and distributor. Allows for reinitializa-
tion of certain program and configure settings.
3700 Portable Samplers
Section 3 Programming Guidelines
1
3
/
/
or
4
8
3-11