3700 Portable Samplers
Appendix D Display Index
This display appears if you select "TIME" in Display #40. Enter the amount of time each bottle is to receive samples.
This display appears if you select "TIME" in Display #41. Enter the amount of time each bottle set receives samples.
This display appears after you select "SAMPLES" in Display #40. Enter the number of samples each bottle receives.
This display appears after you select "SAMPLES/BTL" in Display #41. Enter the number of samples each bottle set is
to receive.
This display appears when you select "yes"" in Display #95. Enter the time of the first bottle switch. The remaining
bottle changes will occur according to settings entered in Display #42. The display will also appear if you have started
the routine after the programmed switch time.
This display appears when you select "YES" in Display #95. Enter the time of the first-bottle set switch. The remaining
bottle-set changes will occur according to settings entered in Display #43. The display will also appear if you start the
routine after the programmed switch time.
This display appears when the sampler is configured for 2-, 4-, 8-, 12-, or 24- bottle configurations under uniform time,
flow, or nonuniform time modes of sample pacing. Select "YES" to sample continuously. Select "NO" to stop the sam-
pling routine after the last set of bottles has been filled.
Enter the size of the sample volume. MAX will vary according to the number of samples per bottle and bottle size.
This display appears when you have configured the controller for composite sampling by selecting "1" in Display #221
or #222. Enter the number of composite samples. An entry of "0" instructs the sampler to take samples until a float
shut-off terminates the sampling routine.
This display appears when you select "YES" in Display #242 or select "DISABLE" in Display #240. Enter the mea-
sured suction head. MAX will be the smaller of the suction line length or "20."
This display appears in the program sequence when you have selected "ENABLE" in Display #290. Select "YES" to
use the calibration sequence, "NO" to omit the calibration sequence.
D-4
Table D-1 Display Index (Continued)
Display 42
CHANGE BOTTLES EVERY
-- HOURS -- MINUTES
Display 43
CHANGE SETS EVERY
-- HOURS -- MINUTES
Display 44
CHANGE BOTTLES EVERY
-- SAMPLES
Display 45
CHANGE SETS EVERY
-- SAMPLES
Display 46
FIRST BOTTLE CHANGE
AT
Display 47
FIRST SET CHANGE AT
HH:MM MM/DD
Display 48
SAMPLE CONTINUOUSLY?
[ YES , NO ]
Display 50
SAMPLE VOLUMES OF
--- ml EACH
Display 60
--- COMPOSITE
SAMPLES ( 0 -
Display 70
SUCTION HEAD OF
-- FEET ( 1 -
Display 80
CALIBRATE SAMPLE
VOLUME?
HH:MM MM/DD
( 10 -
)
MAX
)
MAX
)
MAX
[ YES , NO ]