Table 3-3 Sampling Capabilities Through the Program Sequence (Continued)
Calibration
Key Times
Start Times
First Switch Time
Stop/Resume Times
Time-Pacing
STORM Programming (Available through the Extended Mode Only.)
Storm Pacing
Flow-Pacing
Storm Distribution
Sequential
Samples-per-Bottle
Multiplexing
Bottles-per-Sample
Multiplexing
Multiple-Bottle
Compositing
Storm Volumes and Accuracy
Sample Volume
Suction Head
Calibration
Storm Key Times
Delay to First Group Sam-
ple
Delay to Second Group
Sample
Basic & Extended
You can calibrate sample volumes if desired.
Basic & Extended
You can enter specific start times for both time-paced and
flow-paced routines. If you do not enter a start time, Start Time
Delay is used.
Extended
Bottles can be switched after specified time intervals. After the
routine starts, the first switch time allows the first bottle or bottle
set to receive samples for a partial interval. After the first switch,
the remaining sets will receive samples for full time intervals. This
allows you to place the sampler on schedule.
Extended
You can perform intermittent sampling by defining sampling stop
and resume times. You can enter as many as 12 stop and 12
resume times.
Extended
Samples taken at regular time intervals from 1 minute to 99 hours,
59 minutes.
Extended
Samples taken at regular flow intervals. The sampler will totalize
flow intervals of 1 to 9,999 pulses.
Extended
One sample volume placed in each bottle.
Extended
More than one sample volume placed in each bottle. You can
switch bottles after a specified number of samples have been
deposited.
Extended
Sample volumes placed in more than one bottle at each sample
event.
Extended
More than one sample volume placed in a set of bottles. You can
switch bottle sets after a specified number of samples have been
deposited.
Extended
Enter volumes from 10 to 990 ml for the time-paced and
flow-paced segments separately.
Extended
You can enter suction heads from 1 to 20 feet.
Extended
Calibrate sample volumes if desired. Sets calibration using the
timed sample volume only.
Extended
Enter a time of up to 99 minutes to delay the first sample delivered
to the first bottle group. The delay begins after the programmed
start time for the STORM routine. In applications where there is a
flow meter programmed to enable the sampler, the delay begins
after the sampler is enabled.
Extended
A time of up to 99 minutes can be entered to delay the first sample
delivered to the second bottle group, when the second bottle
group receives time-paced samples. The delay begins after the
programmed start time for the STORM routine. In applications
where there is a flow meter programmed to enable the sampler,
the delay begins after the sampler is enabled.
3700 Portable Samplers
Section 3 Programming Guidelines
3-43