Load Stored Program - Teledyne 3700 Installation And Operation Manual

Portable samplers
Table of Contents

Advertisement

3700 Portable Samplers
Section 3 Programming Guidelines
Table 3-3 Sampling Capabilities Through the Program Sequence (Continued)
Start Times
Maximum Flow Interval

3.9.7 Load Stored Program

/
1. Press
ENTER
PROGRAM
2. Access the configure sequence by selecting "CONFIGURE."
3. Press the
LEFT ARROW
the Set Clock configure option.
4. You can load a stored programmed only when the sampler is configured for the extended programming mode. To
verify the programming mode setting, press the
5. Select "EXTENDED." Press the enter/program key to accept the selection.
/
6. Press
ENTER
PROGRAM
7. Select the number of the program you want to load. Select "NONE" when you do not want to load a program.
3-44
Extended
You can enter a specific start time for the STORM routine. If no
start time is entered, the Start Time Delay will be used.
Extended
You can enter maximum period of time between flow-paced sam-
ple events. If this period of time is exceeded, the sampler will ter-
minate the routine.
The Load Stored Program option allows you to load one of as
many as three sampling programs that you have previously
saved with the Save Current Program configure option. After
loading a program, the sampler will adjust the time settings to
current times and dates.
Check the settings before starting the program to be sure they
are appropriate for your application. (Display #255)
The sampler is shipped from the factory with four programs: the
current program and three stored programs, numbered from 1 to
3. All four programs contain the factory default program settings.
Unless you have previously saved a program under one of the
program numbers, you will replace the current program with the
factory default settings by loading a program. When you reini-
tialize the sampler, all four programs return to the default
program settings.
Example: Load Stored Program
to access the interactive state.
. . . STANDBY . . .
10:34:50
[ PROGRAM,
SAMPLER
or
key to scroll through the configure options. The first option displayed is
RIGHT ARROW
SELECT OPTION: (← →)
SET CLOCK
ENTER
SELECT OPTION: (← →)
PROGRAMMING MODE
[BASIC,
PROGRAMMING MODE
to access the Load Stored Program configure option.
SELECT OPTION: (← →)
LOAD STORED PROGRAM
19-JUN-04
]
CONFIGURE
/
key.
PROGRAM
EXTENDED
]