Teledyne 3700 Installation And Operation Manual page 60

Portable samplers
Table of Contents

Advertisement

3700 Portable Samplers
Section 3 Programming Guidelines
Example: Checking the Configure Option Settings (Continued)
23. For the purposes of this example, select "NO" to skip the test. Press
24. If you want to reinitialize the settings, select "YES." The entire RAM – with the exception of the current
pump-count total, bottle-size settings, suction-line settings, and sampler ID – will be reinitialized to factory
settings. The sampler will automatically turn itself off as part of the reinitialization process. Select "NO" if you do
not want to reinitialize the settings. Press the
Example: Time-Paced Sequential Sampling
1. If the sampler is not already on, press the
Press
/
ENTER
PROGRAM
2. Access the program sequence by selecting "PROGRAM." Because "PROGRAM" will already be selected
(blinking), press the
ENTER
3. To enter the interval between samples in time increments, select "TIME." If "TIME" is already blinking, press the
/
key to accept the selection. If "FLOW" is blinking, press the
ENTER
PROGRAM
"TIME" blinks. Then, press the
4. This display requires two entries: one for the hours, one for the minutes. Enter "0" to set the hours at zero. Press
/
to accept the number "0" and move to the minutes entry shown in step 5.
ENTER
PROGRAM
5. Enter "30" to set the minute entry. Press
6. For this example, select "NO."Press the
to this question, you can select bottles-per-sample or samples-per-bottle multiplexing for your routine.
7. Enter the sample volume: "250." Press
3-26
PUMP COUNT TEST
OFF/ON
TEST DISTRIBUTOR
[YES,
ENTER
REINITIALIZE?
YES
[
The steps in Example Time-Paced Sequential Sampling program
the sampler to take samples every 30 minutes. Each bottle is to
receive one 250 ml sample volume. The sampling routine is to
begin according to the start time delay: one minute after you
press the
START SAMPLING
/
ON
OFF
to access the interactive state
. . . STANDBY . . .
5:34:50
/
key to accept it and move to the next step.
PROGRAM
[
PROGRAM
SAMPLER
/
key to accept "TIME."
ENTER
PROGRAM
[
TIME
PACED SAMPLING
SAMPLE EVERY
0 HOURS,
/
ENTER
PROGRAM
SAMPLE EVERY
0 HOURS,
/
ENTER
PROGRAM
MULTIPLEX SAMPLES?
[ YES ,
/
ENTER
PROGRAM
SAMPLE VOLUMES OF
250
ml
= 105
/
ENTER
PROGRAM
NO
]
/
key to accept the selection
PROGRAM
, NO]
key.
key to turn it on. The standby display shown here will appear.
19-JUN-04
, CONFIGURE ]
, FLOW]
1 MINUTES
to accept the entry.
30
MINUTES
key to accept the entry. If you select "YES" in response
]
NO
to accept the entry.
(10 - 1000)
to accept the selection
key once so that
LEFT ARROW

Advertisement

Table of Contents
loading