This display is part of the calibration sequence. Press the
the distributor and the suction line is in place.
Display 81
This display is part of the calibration sequence. When it first appears, it reports the programmed sample volume. If
the measured volume differs from the reported volume, enter the measured volume here.
Display 82
This display is part of the calibration sequence and appears if the measured volume and the programmed volume dif-
fer by a factor of two or more. Select "YES" to confirm the number entered in Display #82. Select "NO" to return to
Display #82.
Display 83
Select "YES" to enter a start time. "NO" will begin the sampling routine according to the delay set in Display #310.
This display appears when you have selected "YES" in Display #90. Enter the start time and date for the first sample
event. This display will also appear if you have initiated the routine after a programmed start time so that you can
reprogram the start time.
Display 91
This display appears when you have selected "YES" in Display #90. Enter the start time and date for the flow -pulse
countdown. This display will also appear if you have initiated the routine after a programmed start time so that you
can reprogram the start time.
Display 92
This display is the last display of the storm branch. It appears when you select "YES" in Display #90. Enter the start
time for the storm-sampling routine. The sampler will disregard enable or disable signals from the flow meter until the
start time you enter here.
Display 93
This display appears when you have selected "TIME" in either Display #40 or 41. Select "YES" if you want to specify
a clock time for the first bottle or bottle set switch. Select "NO" if you want to begin the switch interval at the routine's
start time.
Display 95
This display appears when you select "ENABLE" in Display #300. Enter the number of stop and resume times.
Display 100
This display appears when the setting in Display #100 is greater than zero. Enter the appropriate stop time.
Display 101
This display appears when the setting in Display #100 is greater than one. It follows Display #101. Enter the appropri-
ate resume time.
Display 102
Table D-1 Display Index (Continued)
PRESS MANUAL SAMPLE
KEY WHEN READY...
--- ml VOLUME
DELIVERED
---ml! ARE YOU
SURE? [ YES , NO ]
90
ENTER START TIME?
[ YES , NO ]
TAKE FIRST SAMPLE AT
HH:MM DD-MMM
START FLOW COUNT AT
HH:MM DD-MM
STORM ENABLED AFTER
HH:MM
ENTER FIRST SWITCH
TIME?
-- STOP or RESUME
TIMES
STOP SAMPLING AT
1.
HH:MMDD-MMM
RESUME SAMPLING AT
HH:MMDD-MMM
1.
key when a collection bottle is underneath
MANUAL SAMPLE
DD-MM
[ YES , NO ]
( 0 - 24 )
3700 Portable Samplers
Appendix D Display Index
D-5