Section 3 Programming Guidelines
Example: Flow-Paced Sampling / Time-Based Bottle Sets (Continued)
14. To start the sampling routine with the first bottle, accept the blinking "1" by pressing the
you want to start the routine with another bottle, enter the starting bottle number here.
This display appears after you press the
reported on the first line. The second line reports the current time and date.
This display alternates with the display illustrated below. The first line indicates the sample event number and the
bottle numbers of the current bottle set. The second line is used to indicate the number of flow pulses remaining until
the sample event is initiated.
This display indicates the time and date of the next bottle set change.
This display appears when the sample event is initiated. It reports the sample number and the receiving bottle
number on the first line during the pre-sample purge.
When the pump begins to run forward to deliver the sample, the second line appears; it reports the sample volume.
When the sample delivery has been completed for the first bottle of the set, the distributor moves to the second
bottle.
After the bottles of the set have each received a sample volume, the alternating pair of displays reappear.
When the next sample event occurs, this display reports the current sample event and the current bottle. When the
sample delivery is completed, the distributor will move to the next bottle of the set and the following display will
appear.
This cycle will be repeated, as samples are deposited in the bottles of the set. The sample number will increase with
each sample deposited until the set change.
When the bottle sets are changed, the sample event number is reset to one. The bottle numbers of the new current
set is reported.
3-88
START SAMPLING
1
AT BOTTLE
(1-23)
key to start the routine. The scheduled start time is
START SAMPLING
START FLOW COUNT AT
10:39
19-06
JUN
SAMPLE 1,
BTLS
1- 2
AFTER
1000 PULSES
NEXT SET CHANGE
AT 12:00
19-JUN
SAMPLE 1,
BOTTLE 1
SAMPLE 1,
BOTTLE 1
PUMPING 100 ml
SAMPLE 1, BOTTLE 2
PUMPING 100 ml
SAMPLE 2, BTLS
1- 2
AFTER
1000 PULSES
NEXT SET CHANGE
AT 12:00
19-JUN
SAMPLE 2,
BOTTLE 1
SAMPLE 2,
BOTTLE 1
PUMPING 100 ml
SAMPLE 2, BOTTLE 2
PUMPING 100 ml
/
key. If