Auto Arming A1
04 - TimeZone 4 Name
Press

3. Use the [] and [] keys to scroll through the list of
timezones until you reach the required one for the
chosen area.
4. Press [OK] to save and exit, or press [MENU] to exit
without saving.
Areas > Timers >

Exit Time

This menu allows the master user to modify the exit timer
for the selected area. Each area in the system can have a
different exit time if required. The exit time is the amount
of time you have to leave the area once it has been turned
on. The keypad will sound an exit warning beep during
this time to let you and other users know that the area is
arming. An alarm cannot be triggered until the exit time
has expired.
Enter programming mode (PIN + MENU) then,
1. Enter [MENU] + [2] + [8] + [0].
A list of available areas will display on the keypad.
A1 Reception Area
A2 Sales Dept
A3 Administration Dept
Press

2. Use the [] and [] keys to select the area that you
want to program the exit time for, then press [OK] to
select. Alternatively, you can enter the area number
that you want to program, then press [OK].
The keypad will display the following:
Exit Time A1
060 Seconds
Press 0-9 OK to SAVE
3. Use the numeric keys to enter the required time in
seconds and then press [OK]. Exit time can be set
from 0 to 255 seconds.
Areas > Timers >

Entry Time 1

This menu allows the master user to modify the entry timer
number 1 for the selected area. Each area in the system
can have a different entry time if required. Your installer
will have set up one or more entry zones per area on your
system and the zones may have been programmed to
follow either entry time 1 or entry time 2.
The entry time is the amount of time you have to turn your
alarm system off once the entry zone have been triggered
or opened.
Bosch Security Systems 12/14 BLCC610U
0-9 OK to SAVE
MENU 2-8-0
OK or MENU
MENU 2-8-1
The keypad will sound an entry warning beep during this
time to let you and other users know that the area needs
to be disarmed.
If the area is not disarmed before the entry time expires
then an alarm will occur.
Enter programming mode (PIN + MENU) then,
1. Enter [MENU] + [2] + [8] + [1].
A list of available areas will display on the keypad.
A1 Reception Area
A2 Sales Dept
A3 Administration Dept
Press

2. Use the [] and [] keys to select the area that you
want to program the entry time for, then press
[OK] to select. Alternatively, you can enter the area
number that you want to program, then press [OK].
The keypad will display the following:
Entry Time 1 A1
020 Seconds
Press 0-9 OK to SAVE
3. Use the numeric keys to enter the required time in
seconds and then press [OK]. Entry time 1 can be set
from 0 to 255 seconds.
Areas > Timers >

Entry Time 2

This menu allows the master user to modify the entry timer
number 2 for the selected area. Each area in the system
can have a different entry time if required. Your installer
will have set up one or more entry zones per area on your
system and the zones may have been programmed to
follow either entry time 1 or entry time 2.
The entry time is the amount of time you have to turn your
alarm system off once the entry zone have been triggered
or opened.
The keypad will sound an entry warning beep during this
time to let you and other users know that the area needs
to be disarmed.
If the area is not disarmed before the entry time expires
then an alarm will occur.
Enter programming mode (PIN + MENU) then,
1. Enter [MENU] + [2] + [8] + [2].
A list of available areas will display on the keypad.
A1 Reception Area
A2 Sales Dept
A3 Administration Dept
Press

2. Use the [] and [] keys to select the area that you
Solution 6000
User Guide
OK or MENU
MENU 2-8-2
OK or MENU
21