ICP-VR8488 | Quick Reference Guide | 9.0

Exit Time (AWAY/STAY Modes)

Location
470 to 471
Increments of 1 sec
(0 sec to 15 sec)
Increments of 16 sec
(0 sec to 240 sec)

Entry Guard Time For STAY Mode

472 to 473
Location
Increments of 1 sec
(0 sec to 15 sec)
Increments of 16 sec
(0 sec to 240 sec)

Delay Alarm Report Time

Location
474 to 475
Increments of 1 sec
(0 sec to 15 sec)
Increments of 16 sec
(0 sec to 240 sec)

Sensor Watch Time

Location
476 to 477
Increments of days
(tens digit)
Increments of days
(units digit)

Codepad Lockout Time

478
Location
Default
0
0
No lockout
1 to 15
Increments of 10 sec
(10 sec to 150 sec)

Siren Run Time

Location
479
5
Default
0
No siren time
1 to 15
Increments of 1 min
(1 min to 15 min)

Siren Sound Rate

Location
480
Default
7
0 to 15
0 = slowest frequency
15 = fastest frequency

Auto Arming Pre-Alert Time

Location
481
Default
1
0
No pre-alert time
1 to 15
Increments of 5 min
(5 min to 75 min)
Bosch Security Systems, Inc. | 12/08 | F01U089640-01
Programming Guide

Auto Arming Time

Location
Default
470
12
471
3

Auto Disarming Time

Location
Default
472
0
473
0

Kiss-Off Wait Time

Location
Default
474
0
475
0

Speaker Beep Volume

Location
Default
476
0

System Options 1

477
0

System Options 2

System Options 3

System Options 4

Location
482 to 485
Hour of the day (tens digit)
Hour of the day (units digit)
Minute of the day (tens digit)
Minute of the day (units digit)
Location
486 to 489
Hour of the day (tens digit)
Hour of the day (units digit)
Minute of the day (tens digit)
Minute of the day (units digit)
Location
490
3
Default
Increments of 500 ms
(500 ms to 8 sec)
491
Location
Default
13
0 to 15
0 = no beeps
15 = loudest beeps
Location
492
1
Bosch smart lockout allowed
2
Horn speaker monitor
4
Strobe indication for radio arm/disarm
8
Assign Button 4 on transmitter to operate STAY
Mode
493
Location
Default
0
1
Codepad panic to be silent
2
Codepad fire to be silent
4
Codepad medical to be silent
8
Access denied (code retries) to be silent
Location
494
1
AC fail after 1 hour (Disabled = after 2 min)
2
Ignore AC fail
4
Pulse count handover allowed
8
Handover delay to be sequential
495
Location
Default
0
1
Panel to power up disarmed (if power reset)
2
Arm/disarm tracking on power up
4
Internal crystal to keep time
8
Night arm station or RE005 installed
EN | 25
Location
Default
482
0
483
0
484
0
485
0
Location
Default
486
0
487
0
488
0
489
0

Hide quick links: