Chapter 15 DRYPRO 832 Utility Tool
15.20.3 Creating QC PATTERN BASE
When the QC pattern is printed, the average of the first 3 readings of the built-in densitometer becomes the QC
PATTERN BASE. As the printed QC PATTERN is always registered as the base value for image checking or density
checking, the base value is created by printing 3 QC PATTERNS after resetting the base value.
1
Click the [QC PATTERN] button.
The "QC PATTERN" window appears.
2
Click the [RESET] button.
The base value for the previous QC PATTERN is reset.