Replacing Deodorant Fan - Konica Minolta drypro 832 Service Manual

Laser imager
Hide thumbs Also See for drypro 832:
Table of Contents

Advertisement

Chapter 9 Replacing Loading Parts in Heat Process Unit
9.2.5

Replacing Deodorant Fan

Replace the fan unit that removes the odor from the inside of the main unit.
Be sure to turn off power and remove the power cable from the electrical outlet before removing
or installing the exterior cover or replacing loading parts.
Caution
Work outline
The number of personnel and the estimated work hours required to replace loading parts is as follows:
Number of
Personnel
1
Requirements
The procedure for replacing loading parts requires the following tools:
No.
1
Various types of screwdrivers
3
Fan unit (for replacement)
9-20
Work Hours
5 minutes
Tools
No.
2
1
Pull the tray shutter out of the lower part of the
supply tray.
2
Insert the tray shutter into the slot in the upper
part of the supply tray with the tray shutter's UP
mark on the top surface toward you.
Inserting the tray shutter as far as it will go unlocks and
causes it to pop out several centimeters.
Caution
3
Remove the rear cover.
• Six screws (M4×8)
Note
Tools
Tray (container for screws and parts removed)
When replacing loading parts, be sure to
replace with the tray shutter attached.
If some of the film remains on the tray, the
film may be exposed.
Take sufficient care when handling the
tray shutter, as it may be impossible to
insert if it becomes deformed due to
rough handling.
If you feel any resistance when inserting
the tray shutter, stop the procedure and
refer to
"17.1.7 Pickup malfunction
trouble (Page 17-6)"
to fix the problem.
Remove the upper two screws and the one screw
in the center from the rear cover and loosen the
bottom three screws.