Printing Operation Load Timing Chart (Standard 2 Ch); Printing Operation Load Timing Chart - Konica Minolta drypro 832 Service Manual

Laser imager
Hide thumbs Also See for drypro 832:
Table of Contents

Advertisement

18.8 Printing Operation Load Timing Chart (Standard 2 ch)

PC
Main Unit
Control
Print Unit
Default Data Instructions
MEC Unit
Initial operation after
turning on main unit
Power ON
Print Start
Request
Pickup Unit
Pickup
HP motor
Pickup
HP Sen
Pickup
Pulse Motor
Also perform operation
for Tray 1 if available.
Elev HP
Sen
Elev HP Sen
Raise
Up-down Plate
Operation
Correct
DC Motor
Opposite
Detection
Film Height
Detection Sen
Lower
Elev Trans Unit
Nip Opening/
Closing Motor
Nip Opening/
Closing Sen
Open
Outlet Sen
Trans Motor
500HZ
400HZ
3745Hz 100mm/s half 300ms
Justification Unit
Pos Regulation
Inlet Sen
3745Hz
400Hz half 50ms
Reverse 400HZ
2s
Position Restriction
Pulse Motor
Reverse 400HZ
Stop 10ms
300ms
Sub Scan
Sub Scan
Inlet Sen
Sub Scan
Pulse Motor
ON
Sub Scan Nip
DC Motor
Stop
ON
Sub Scan
Nip Sen
Vsic Sen
Main unit remains on
during heating even
after the initial
operation is completed.
Heat Process
Drive DC Motor
500HZ
1794Hz 32.5mm/sec half 200ms
Ejection Motor
1794HZ
Densitometer
Ent Sen
18-30
Image Processing, Printing Operation
Omitted because this is the
same as standard 1 channel
Supply Instructions
Film Loading
Omitted because this is the
same as standard 1 channel
HP Pos
Stop
Close
Open
3231Hz
500Hz half 200ms
5s
500HZ
1616Hz 50mm/s half 100ms
3231Hz 100mm/s half 200ms
1616HZ
3231Hz 100mm/s half 100ms
OFF
4000Hz half 50ms
Stop
4000Hz half 50ms
400HZ
1873Hz 50mm/s half 100ms
1873Hz
3745Hz 100mm/s half 100ms
OFF
25s
Stop
Home Position
Both Nip Position
OFF
Heating Completed
25s
25s
500Hz half 200ms
OFF
Supply Completed Notification
Printing Operation
6092Hz
500Hz half 200ms
620ms
500Hz
3046Hz 50mm/s half
Turn on position restriction sensor or start
deceleration at 920-ms high-speed process
3231Hz
500Hz half 200ms
600ms
850ms
3745HZ
1236Hz 33mm/s half 200ms
600ms
1236
400 half 50ms
850ms
300ms
3212.7HZ
1000ms
750ms
Inlet Nip Position
t1 0.5s
Measure this operation time
= Nip 50 operation time
1322HZ Control Gain Use "H"
Exposure Instructions
Exposure Completed Notification
t3 By film size
(Film length - 60)/33 - Nip 250 operation time -standby
time t1
* When the film is at the exit strong position,
Reverse 4000HZ
400Hz half 50ms
set the back end of the film 60 mm in front of V-sync.
14 × 17 inch-film 430 mm
14 × 14 inch-film 354 mm
Reverse 400HZ
4000Hz half 50ms
11 × 14 inch-film 279 mm
10 × 12 inch-film 303.2 mm
8 × 10 inch-film 252.8 mm
500Hz half 200ms
3212.7Hz
500Hz half 200ms
500HZ
3212.7Hz 33mm/s half 200ms
Both Nip Position
Outlet Nip Position
t5 1100ms
t3 By film size
t2 165
t4 85
Operation
Operation
Time
Time
500HZ
1794Hz 32.5mm/sec half 200ms
t 1s
1794HZ
6 5521HZ
500Hz half 200ms
5521Hz 100mm/s half 200ms

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents