Chapter 7 Replacing Sub Scan Unit Loading Parts
11
Install the cover removed in
• Two screws (M3×6)
12
Close the external guide unit assembly opened in
13
Install the upper right cover, connector cover, film ejection tray, LAN cover, lower right cover,
and right cover with reference to
Installing Upper Right
14
Return the supply tray and tray shutter to their original positions.
Take sufficient care when handling the tray shutter, as it may be impossible to insert if it
becomes deformed due to rough handling.
Caution
This is the end of the process of replacing the right cover detection sensor.
7-14
step
5.
"