8.31

L55, cabinet anti-condensation heating

Availability of option
This option is available for the following S120 Cabinet Modules:
● Line Connection Modules
● Basic Line Modules
● Smart Line Modules
● Active Line Modules
● Booksize Base Cabinets
● Chassis format Motor Modules
● Auxiliary Power Supply Modules
Description
The cabinet anti-condensation heating can be used at low ambient temperatures and high
levels of humidity to prevent the formation of condensation.
A 100 W heater (-E240) is used for 400 mm and 600 mm cabinets. Two 100 W heaters (-
E240, -E241) are used for cabinet widths of 800 mm or higher.
The power supply (110 to 230 V AC) must be provided externally and protected with a fuse
of up to 10 A.
X240 connection for cabinet anti-condensation heating
Table 8- 51
Terminal
1
2
3
Max. connectable cross-section: 4 mm²
Since the voltage is supplied from an external source, voltage may still be present in the
cabinets even when the main breakers in all units are open.
You must observe the "five safety rules" when carrying out maintenance work.
Cabinet Modules
Manual, (GH5), 05/2010, A5E03263538A
Terminal block X240
Designation
L1
N
PE
DANGER
8.31 L55, cabinet anti-condensation heating
Technical data
110 to 230 V AC voltage supply
Current demand:
- min.: approx. 0.43 A (for 230 V AC, 100 W)
- max.: approx. 1.8 A (for 110 V AC, 200 W)
Protective conductor
Options