8.11 K51, VSM10 Voltage Sensing Module Cabinet-Mounted

8.11
K51, VSM10 Voltage Sensing Module Cabinet-Mounted
Availability of option
This option is available for the following S120 Cabinet Modules:
● Chassis format Motor Modules
Description
Voltage recording module VSM10 is used to operate a permanent-field synchronous
machine without encoder with the requirement for switching to a machine which is already
running (flying restart function).
The terminals on the Voltage Sensing Module (-T1-B51) are pre-assigned in the factory and
must not be changed by the customer.
To commission the function, the permanent-field synchronous machine without encoder
must be input and "Flying restart" activated with p1200.